Electrolux & Zanussi Glass washer Parameter Code



dishwasher troubleshooting|glass washer service manual|dishwasher error code|service errors
hood type dishwasher|electrical wiring diagram|parameter.

Maintaining commercial kitchen equipment helps keep your kitchen best to be familiar with
the restaurant and Hotel equipment by reviewing the owner's manual to Contact a professional 
repair technician to conduct regular planned

Zanussi|Electrolux|fagor|winterhalter|hobart|meiko|comenda|dhir



Note : Subscribe E-Mail and YouTube to get more information,we are ready to help you our best
don't hesitate to contact us.
 Electrolux and Zanussi Dishwasher | Electrolux and Zanussi Glasswasher
 KEYBOARDS
 HOODTYPE Style
 UNDERCOUNTER Style 
 SETTING MODES:
 To enter into one setting mode the appliance should be in stand-by: switch on the
 appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not
 simultaneously pressure of the two keys. 
 Enter into General Parameters                                                Enter into Factory Parameters
 (Hold down buttons for at least  five seconds).               (Hold down buttons for at least  five seconds)
 SETTING MODES:
 To enter into one setting mode the appliance should be in stand-by: switch on the
 appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not
 simultaneously pressure of the two keys.  

 
Zanussi Dishwasher|Electrolux Dishwasher A  Alarms that stop the dishwasher Remedy

 A1 Error Want of water 
 Is the water open?| Does the water load solenoid valve work?
 Is the water feed flow a min. of 5 l/min?
 Is the water inlet filter clean?
 Is the load solenoid valve filter clean?
 Is the overflow inserted?
 Is the main board (ATM-PRES) CN2 connector correctly positioned?
 Do the tank/boiler pressure switches work properly?
 C8 Error During rinse phase boiler doesn't empty
 Are the rinse arms clogged?
 Does the rinse pump work correctly?
 Is there water in the level sensor tube?
 Is there scale in the boiler?
 Does the boiler level sensor work properly?

 C9 Error Automatic hood out of order 
 See par. C1 - Alarm codes for automatic hood type dishwashers
 When the alarm C9 appears, to facilitate fault-finding another parameter providing a more 
 detailed indication has been introduced.
 B1 Error Drain not efficient
 Has the overflow been removed?
 Is the water drain blocked?
 Is the drain pump blocked?
 Are the air trap and tank pressure switch clean?
 Is there a constriction in the drain tube?
 Is the pump breather pipe returning to the tank clogged or constricted?
 Does the tank pressure switch work properly?
 Is there a hole in the drain tube (only for versions with drain pump)? 
 B2 Error Overflow alarm 
 Is the water drain blocked?
 Are the air trap and tank pressure switch clean?
 Does the tank pressure switch work properly?
 Is the load solenoid valve blocked? (E1 - LOAD_EV)
 Is the load solenoid valve relay stuck? (RL8 - LOAD_EV) 

 C1 Error Boiler temperature rise too fast 
 Does the boiler level sensor work properly?  The boiler could be empty
 Are non-original power resistances installed?

 C2 Error Boiler temperature too high
 Has the boiler temperature been changed (btC - increased above 90°C)?
 Has the software alarm value been modified (bHi)?
 Does the boiler level sensor work properly?
 Is the boiler relay stuck (see RL2, RL3, RL4)?
 
 C3 Error Tank temperature too high
 Is the feed water above 60°C?
 Has the software alarm value been modified (bHi)?
 Is the rinse water temperature too high?
 Is the tank relay stuck (RL5 - TUB_HEAT)?

 C4 Error Tank temperature sensor out of order
 Is the temperature sensor broken or disconnected (NT1)? 
 Is the temperature sensor connector correctly inserted? 

 C6 Error Boiler temperature sensor out of order 
 C7 Error Boiler temperature sensor out of order 
 C10 Error Rinse temperature sensor out of order
 C11 Error
 E1 Error Communication error 
 Is the connection between main board and control panel correct? Are the connectors 
 correctly connected?
 Are connector contacts clean?
 
 E2 Error Tank temperature low
 Does the tank heating element work properly? 
 Are the connectors correctly connected?
 Are the dishwasher feed voltage and current correct?
 Is the relay RL5 on the board disconnected or faulty?

 E3 Error Boiler temperature low
 Does/do the boiler heating element/s work properly?
 Are the connectors correctly connected?
 Does the possible remote control switch connected to the heating element work correctly?
 Is there power at the remote control switch input terminals?
 Does relay RL2 on the board work properly? 

 F21 Error  Water softener operation errors
 This alarm appears in case of malfunctioning in the continuous water softener. 
 To reset errorF21 it is necessary to disconnect and reconnect the main power supply to the
 machine by means of the main switch on the external power board.

 F22 Error Communication errors between the mother board and softener board
 This alarm appears in case of problems in communication between the mother board and water     softener board; check the connection between mother board connector J1 and water softener   connector ST8.

DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER
Dishwashers with incorporated continuous water softener have a continuous softener in the water circuit. By means of special resins, this device removes the calcareous substances from the feed water, supplying decalcified water for washing. 
To activate the continuous water softener, set the parameter SER (in the HCP family) to the value 9 or the value 11 if the water softener board is connected to the LK485 board.

For the continuous softener to work properly the resins must be regenerated periodically with a frequency depending on the
hardness of the inlet water, the number of wash cycles carried out and the max. hardness set with the parameter SrU (in the CFG family)Unlike conventional water softeners, this continuous softener does not require machine stops for regenerating the resins. 
To regenerate the resins it is necessary to put coarse salt in the special container located in the dishwasher.
In particular, the salt container must be filled when the dishwasher is used for the first time and whenever the messages SAL 0 or SAL END are displayed at the start or end of a wash cycle. The salt container holds up to 1.5 kg of salt.
CAUTION: use only coarse salt with a NaCl purity grade of 99.8 %. The use of salt with a lower 
purity grade may cause the sale container filter to clog and the water softener to malfunction.

IMPORTANT: The messages
SAL 0 or SAL End may appear for several wash cycles even after topping-up the
salt, as the salt must circulate in the entire system. Correct operation of the dishwasher is not, 
however, affected. 
The number of regeneration cycles performed can be checked by consulting the parameter
nrE in the Cnt family of counters.

nrE only counts regeneration cycles carried out with the salt container adequately filled; 
there is another counter, rES (in the Cnt family) that indicates the number of regeneration 
cycles done without salt.
If the parameter
SrU is set to the value10, according to the factory setting, the water softener outlet 
water hardness can vary between 3°fH - 10 °fH/ 1.7 °dH - 5.6 °dH / 2.1 °cH - 7 ° cH.

AUTONOMY OF A COLUMN OF RESINS ACCORDING TO THE CHANGE IN INLET 
WATER HARDNESS, WITH OUTLET WATER HARDNESS OF 10 °fH / 5.6 °dH /7 °cH
(SrU =10 according to the factory setting).

Alarms that don’t stop the dishwasher for models with incorporated
continuous water softener 

If alarm F21 or F22 appears, the machine indicates it on the display at regular intervals and 
auto-configures itself in the same way as a machine without water softener. 
Resin regeneration cycles are not performed and the column used for filling is always 
the same (column B).
Alarm F21 is reset when the machine is switched off and on from the mains switch 
(only if the causes that generated it have been eliminated).
Alarm F22 is reset when the machine is switched off and on from the user interface or from 
the main switch(only if the causes that generated it have been eliminated). 